A1 PULLEY: AN ANATOMIC STUDY OF BIOMECHANICAL PROPERTIES WITH IMPLICATION IN TRIGGER FINGER RELEASE
Abstract
Purpose: Trigger finger is a common problem leading to hand incapacitation disproportionate to the pathology. The simple complete release of A1 pulley for triggering is based on the premise that its functionality is minimal, and sacrifice will lead to negligible drawbacks. This anatomical study objectively assesses A1 pulley function and evaluates biomechanical disadvantages of its sacrifice.
Methods: An anatomic study on fresh cadavers and amputated upper extremities was conducted to assess the role of A1 flexor pulley in digit function. With all pulleys intact, tendon excursion needed to attain complete finger flexion and force required to attain so were measured for each digit. These parameters were reassessed after partial ‘functional’ pulley release by the technique of ‘N enlargement’ plasty, and standard complete A1 pulley release. A statistical analysis of biomechanics of intact A1 pulley, and after the standard or ‘N’ plasty techniques is done.
Results: In five upper limbs, twenty-five digits were sequentially analyzed. The increased force and tendon excursion required after A1 pulley release is statistically significant compared to intact pulley or ‘N’ plasty partial release.
Conclusion: Complete finger flexion after standard release of A1 pulley, requires statistically significant increased force and tendon excursion than with the pulley intact or partially enlarged.
Clinical Relevance: A1 pulley has significant role in hand biomechanics and should be preserved whenever feasible. ‘N’ plasty is a simple and effective technique to enlarge A1 pulley while preserving significant function.
Keywords
Full Text:
PDFReferences
Giugale JM, Fowler JR. Trigger Finger. Orthop Clin North Am. 2015;46(4):561-569. doi:10.1016/j.ocl.2015.06.014.
Akhtar S, Bradley MJ, Quinton DN, Burke FD. Management and referral for trigger finger/thumb. BMJ. 2005;331(7507):30-33. doi:10.1136/bmj.331.7507.30.
Patel MR, Bassini L. Trigger fingers and thumb: when to splint, inject, or operate. J Hand Surg Am. 1992;17(1):110-113. http://www.ncbi.nlm.nih.gov/pubmed/1538090. Accessed July 29, 2018.
Kazuki K, Egi T, Okada M, Takaoka K. CLINICAL OUTCOME OF EXTRASYNOVIAL STEROID INJECTION FOR TRIGGER FINGER. Hand Surg. 2006;11(01n02):1-4. doi:10.1142/S0218810406003115.
Cebesoy O, Karakurum G, Kose KC, Baltaci ET, Isik M. Percutaneous release of the trigger thumb: is it safe, cheap and effective? Int Orthop. 2007;31(3):345-349. doi:10.1007/s00264-006-0180-1.
Pegoli L, Cavalli E, Cortese P, Parolo C, Pajardi G. A COMPARISON OF ENDOSCOPIC AND OPEN TRIGGER FINGER RELEASE. Hand Surg. 2008;13(03):147-151. doi:10.1142/S0218810408003992.
Masquijo JJ, Ferreyra A, Lanfranchi L, Torres-Gomez A, Allende V. Percutaneous Trigger Thumb Release in Children. J Pediatr Orthop. 2014. doi:10.1097/BPO.0000000000000119.
Dunn MJ, Pess GM. Percutaneous trigger finger release: a comparison of a new push knife and a 19-gauge needle in a cadaveric model. J Hand Surg Am. 1999;24(4):860-865. http://www.ncbi.nlm.nih.gov/pubmed/10447182. Accessed July 28, 2018.
Niumsawatt V, Mao D, Salerno S, Rozen WM. Trigger Finger Release With Stepwise Preservation of the A1 Pulley: A Functional Pulley-Preserving Technique. Int Surg. 2013;98(4):437-444. doi:10.9738/INTSURG-D-13-00028.1.
Amirouche F, Gonzalez M, Koldoff J, Tioco J, Ham K. A biomechanical study of the finger pulley system during repair. Technol Health Care. 2002;10(1):23-31. http://www.ncbi.nlm.nih.gov/pubmed/11847445.
Phillips C, Mass D. Mechanical analysis of the palmar aponeurosis pulley in human cadavers. J Hand Surg Am. 1996;21(2):240-244. doi:10.1016/S0363-5023(96)80107-9.
CONKLIN JE, WHITE WL. Stenosing tenosynovitis and its possible relation to the carpal tunnel syndrome. Surg Clin North Am. 1960;40:531-540. http://www.ncbi.nlm.nih.gov/pubmed/13811512.
Doyle JR. Anatomy of the finger flexor tendon sheath and pulley system. J Hand Surg Am. 1988. doi:10.1016/S0363-5023(88)80082-0.
Doyle JR, Blythe WF. Anatomy of the flexor tendon sheath and pulleys of the thumb. J Hand Surg Am. 1977;2(2):149-151. doi:10.1016/S0363-5023(77)80101-9.
TOMAINO M, MITSIONIS G, BASITIDAS J, GREWAL R, PFAEFFLE J. The Effect of Partial Excision of the A2 and A4 Pulleys on the Biomechanics of Finger Flexion. J Hand Surg Am. 1998;23(1):50-52. doi:10.1016/S0266-7681(98)80218-0.
Ryzewicz M, Wolf JM. Trigger Digits: Principles, Management, and Complications.; 2006. http://www.scottsevinsky.com/pt/reference/hand/johs_trigger_digits.pdf. Accessed July 29, 2018.
Mitsionis G, Bastidas JA, Grewal R, Pfaeffle HJ, Fischer KJ, Tomaino MM. Feasibility of partial A2 and A4 pulley excision: Effect on finger flexor tendon biomechanics. J Hand Surg Am. 1999;24(2):310-314. doi:10.1053/JHSU.1999.0310.
Rispler D, Greenwald D, Shumway S, Allan C, Mass D. Efficiency of the flexor tendon pulley system in human cadaver hands. J Hand Surg Am. 1996;21(3):444-450. doi:10.1016/S0363-5023(96)80361-3.
Su. F-C. Biomechanical Aspects of Trigger Finger. Pacifico Yokohama.HW-I-1. In: The 8th International Hand and Wrist Biomechanics Symposium. ; 2012:Apr20-21.
Boretto J, Alfie V, Donndorff A, Gallucci G, DE Carli P. A prospective clinical study of the A1 pulley in trigger thumbs. J Hand Surg Eur Vol. 2008;33(3):260-265. doi:10.1177/1753193408087070.
Low CK, Pereira BP, Ng RT, Low YP, Wong HP. The effect of the extent of A1 pulley release on the force required to flex the digits. A cadaver study on the thumb, middle and ring fingers. J Hand Surg Br. 1998;23(1):46-49. doi:10.1016/S0266-7681(98)80217-9.
Bayat A, Shaaban H, Giakas G, Lees VC. The pulley system of the thumb: Anatomic and biomechanical study. J Hand Surg Am. 2002;27(4):628-635. doi:10.1053/jhsu.2002.34008.
Kumar P, Chakrabarti I. Idiopathic carpal tunnel syndrome and trigger finger: is there an association? J Hand Surg Eur Vol. 2009;34(1):58-59. doi:10.1177/1753193408096015.
HOMBAL JWR, OWEN R. Carpal Tunnel Decompression and Trigger Digits. Hand. 1970;2(2):192-196. doi:10.1016/0072-968X(70)90022-7.
Schöffl I, Baier T, Schöffl V. Flap Irritation Phenomenon (FLIP): Etiology of Chronic Tenosynovitis After Finger Pulley Rupture. Vol 27.; 2011. https://pdfs.semanticscholar.org/f9ee/9c59b44d5ceffab20b0e2a3ba088f7eed74e.pdf. Accessed July 30, 2018.
Refbacks
- There are currently no refbacks.