EVALUATION AND COMPARISON OF ACCURACY OF CASTS OBTAINED FROM DUAL ARCH TRAYS USING DIFFERENT TYPES OF IMPRESSION MATERIALS. AN IN- VITRO STUDY.
Abstract
AIM: This study aims to evaluate the definiteness of the casts made by making impressions with different impression materials in two types of
double arch trays.
MATERIALS AND METHOD: A total of 60 impressions obtained were grouped into three classes according to impression material studied with
two type of trays used i.e. Class A, class B & class C consisted of impressions obtained from heavy+ light body (n=20), putty + light body (n=20)
and Polyether respectively. Class A, B and C were further divided into Subclass I and II depending upon the metal (n=10) and plastic (n=10) dualarch
trays used. The measurements were obtained using digital microscope and statistical analysis was done for interpretation of results.
RESULTS: All the three classes when compared to the master model showed decreased inter- abutment distance (p> 0.05) The statistical
analysis showed that PVS heavy- light body, & polyether loaded dual arch metal tray are more accurate than plastic tray. Anova shows interabutment
distance with plastic dual arch tray within different impression material found to be statistically significant (p<0.05) whereas in relation
to metal dual arch tray it was found to be statistically insignificant (p> 0.05).
CONCLUSION- For measuring the inter-abutment distance, If metal tray is to used, polyether is found to be more accurate, and if plastic tray is
used, PVS putty-light body is more accurate, whereas PVS (heavy-light body) loaded in a plastic dual arch tray should not be used as it is found
to be least accurate.
Keywords
Full Text:
PDFReferences
Wilson EG, Werrin SR. Double arch impressions for simplified restorative dentistry. J Prosthet Dent 1983;49:198-202.
Donovan TE, Chee WL. A review of contemporary impression materials and techniques. Dent Clin N Am 2004;48: 445-70.
Camerson SM, Whitlock WL, Tabor MS. Foreign body aspiration in dentistry: A review. J Am Dent Assoc 1996;127(8):1224-9.
Breeding LC, Dixon DL. Accuracy of casts generated from dual-arch impressions. J Prosthet Dent 2000;84:403-7.
Barzilay I, Myers ML. The dual arch impression. Quintessence Int 1987;18(4):293-5.
Davis RD, Schwartz RS. Dual-arch and custom tray impression accuracy. Am J Dent 1991;4:89-92.
Schwartz RS, Davis RD. Accuracy of second pour casts using dual-arch impression. Am J Dent 1992;5:192-4.
Ceyhan JA, Johnson GH, Lepe X, Phillips KM. A clinical study comparing the three-dimensional accuracy of a working die generated from two dual arch trays and a complete arch custom tray. J Prosthet Dent 2003;90:228-34.
Ceyhan JA, Johnson GH, Lepe X. The effect of tray selection, viscosity of impression material, and sequence of pour on the accuracy of dies made from dual-arch impressions. J Prosthet Dent 2003;90:143-9.
Christenson GJ. Ensuring accuracy and predictability with double-arch impressions. J Am Dent Assoc. 2008;139:1123-25.
Cox JR, Brandt RL, Hughes HJ. A clinical pilot study of the dimensional accuracy of double-arch and complete-arch impressions. J Prosthet Dent 2002;87:510-5.
Bansal S, Singh K, Saluja BS, Goyal P, Mittal D, Kaur G. Accuracy of metal and plastic dual arch impression trays –A Comparative In Vitro Study. Indian J Dent Sci 2013;5(5):19-23.
Reddy JM, Prashanti E, Kumar GV, Suresh Sajjan MC, Mathew X. A comparative study of interabutment distance of dies made from full arch dual arch impression trays with those made from full arch stock trays: An in vitro study. Indian J Dent Res 2009;20(4):412-7.
Wostmann B, Rehmann P, Balkenhol M. Accuracy of impressions obtained with dual arch trays. Int J Prosthodont 2009;22(2):158-60.
Cox JR. A clinical study comparing marginal and occlusal accuracy of crowns fabricated from double arch and complete arch impressions. Aust Dent J 2005;50(2):90-4.
Jhonson GH, Craig RG. Accuracy of four types of rubber impression materials compared with time of pour and repeat pour of models. J Prosthet Dent 1985;53(4):484-90.
De Lima LM, Borges GA, Junior LH, Spohr AM. In vivo study of the accuracy of dual-arch impressions. J Int Oral Health 2014;6:50-5.
Cayouette MJ, Burgess JO, Jones RE Jr, Yuan CH. Three-dimensional analysis of dual-arch impression trays. Quintessence Int 2003;34:189-98.
Braly BV. Occlusal analysis and treatment planning for restorative dentistry. J Prosthet Dent 1972;27:168-71.
Campbell SD. Comparison of conventional paint-on-die spacer and those used with the all-ceramic restoration. J Prosthet Dent 1990;63:151-5.
International dental standards. 2nd ed. Geneva: International Organization for standardization; 1992. ISO 4823:1992(E):7.8.
Kaplowitz GJ. Trouble-shooting dual arch impressions. J Am Dent Assoc 1996;127:234-40.
Larson TD, Nielsen MA, Brackett WW. The accuracy of dual-arch impression: A pilot study. J Prosthet Dent 2002;87:625-7.
Lane DA, Randall RC, Lane NS, Wilson NHF. A clinical trial to compare double arch and complete arch impression techniques in the provision of indirect restorations. J Prosthet Dent 2003;89:141-5.
Kaplowitz GJ. Trouble-shooting dual arch impressions II. J Am Dent Assoc 1997;128:1277-81.
Refbacks
- There are currently no refbacks.