A SIMPLE TECHNIQUE FOR BEADING AND BOXING OF FULL ARCH IMPLANT IMPRESSIONS

Dr. S. Sankarakrishnan, Dr. S. Sabarinathan, Dr. B. Sivasaranya

Abstract


Axially placed or tilted implants can be used to rehabilitate a completely edentulous arch and immediate loading of such implants is now recommended. Hence the need to make an impression and to provide a provisional prosthesis within a short span of time arises. A working cast would be necessary to execute these procedures.  This article describes a quick method to generate a working cast or a master model using a simple technique for beading and boxing full arch implant impressions.


Keywords


beading and boxing , implant impression

Full Text:

PDF

References


Becker W, Becker BE, Israelson H, et al. One-step surgical placement of Brånemark implants: A prospective clinical study. Int J Oral Maxillofac Implants 1997 ;12:454–462.

Paulo malo , Bo rangert , Miguel Nobre.All-on-4 Immediate function concept with Branemark system implants for completely edentulous maxillae : A 1 year retrospective clinical study. Clinical implant dentistry and related research 2005;7:88-94

Romanos GE .present status in immediate loading of oral implants .J oral implantol 2004 ;30:189-197.

Szmukler-Moncler S, Piattelli A, Favero GA, Dubruille JH. Considerations preliminary to the application of early and immediate loading protocols in dental implantology. Clin Oral Implants Res 2000;11:12–25.

Sang-Jik Lee, Sung-Bum Cho. Accuracy of five implant impression technique: effect of splinting materials and methods. J Adv Prosthodont 2011 ; 3(4): 177–185

Mohammadreza Nakhaei, Azam S Madani, Azizollah Moraditalab, Hamidreza Rajati Haghi.Three-dimensional accuracy of different impression techniques for dental implants. Dent Res J (Isfahan) 2015; 12(5): 431–37.

Richard W. Toth. A trayless impression technique for complete arch implant-supported immediately loaded provisional and definitive restorations. J Prosthet dent 2005; 94 (2) : 202–203.

Asbjorn Jokstad, Hassan Alkumru.Immediate function on the day of surgery compared with a delayed implant loading process in the mandible: a randomized clinical trial over 5 years.Clin Oral Implants Res 2014 ; 25(12): 1325–35.

Rudd KD, Morrow RM, Seldmann EE (1986) Chapter 4: Final impression, boxing and pouring. In: Dental laboratory procedures: volume one: complete dentures, 2nd edn. CV Mosby, St. Louis, pp 57–79.

Bolouri A, Hilger TC, Gowrylok MD. Boxing impressions. J Prosthet Dent. 1975;33:692–695.

Anup Vyas, Kavita Maru,Sandeep Kaur Bali, Sumet Jain,Jyotsna Shukla, Neene Kataria. A new simplified beading and boxing procedure for elastic impression.J Indian Prosthodont Soc. 2011 ;11(1):52-54.


Refbacks

  • There are currently no refbacks.