A SIMPLE TECHNIQUE FOR BEADING AND BOXING OF FULL ARCH IMPLANT IMPRESSIONS
Abstract
Axially placed or tilted implants can be used to rehabilitate a completely edentulous arch and immediate loading of such implants is now recommended. Hence the need to make an impression and to provide a provisional prosthesis within a short span of time arises. A working cast would be necessary to execute these procedures. This article describes a quick method to generate a working cast or a master model using a simple technique for beading and boxing full arch implant impressions.
Keywords
Full Text:
PDFReferences
Becker W, Becker BE, Israelson H, et al. One-step surgical placement of Brånemark implants: A prospective clinical study. Int J Oral Maxillofac Implants 1997 ;12:454–462.
Paulo malo , Bo rangert , Miguel Nobre.All-on-4 Immediate function concept with Branemark system implants for completely edentulous maxillae : A 1 year retrospective clinical study. Clinical implant dentistry and related research 2005;7:88-94
Romanos GE .present status in immediate loading of oral implants .J oral implantol 2004 ;30:189-197.
Szmukler-Moncler S, Piattelli A, Favero GA, Dubruille JH. Considerations preliminary to the application of early and immediate loading protocols in dental implantology. Clin Oral Implants Res 2000;11:12–25.
Sang-Jik Lee, Sung-Bum Cho. Accuracy of five implant impression technique: effect of splinting materials and methods. J Adv Prosthodont 2011 ; 3(4): 177–185
Mohammadreza Nakhaei, Azam S Madani, Azizollah Moraditalab, Hamidreza Rajati Haghi.Three-dimensional accuracy of different impression techniques for dental implants. Dent Res J (Isfahan) 2015; 12(5): 431–37.
Richard W. Toth. A trayless impression technique for complete arch implant-supported immediately loaded provisional and definitive restorations. J Prosthet dent 2005; 94 (2) : 202–203.
Asbjorn Jokstad, Hassan Alkumru.Immediate function on the day of surgery compared with a delayed implant loading process in the mandible: a randomized clinical trial over 5 years.Clin Oral Implants Res 2014 ; 25(12): 1325–35.
Rudd KD, Morrow RM, Seldmann EE (1986) Chapter 4: Final impression, boxing and pouring. In: Dental laboratory procedures: volume one: complete dentures, 2nd edn. CV Mosby, St. Louis, pp 57–79.
Bolouri A, Hilger TC, Gowrylok MD. Boxing impressions. J Prosthet Dent. 1975;33:692–695.
Anup Vyas, Kavita Maru,Sandeep Kaur Bali, Sumet Jain,Jyotsna Shukla, Neene Kataria. A new simplified beading and boxing procedure for elastic impression.J Indian Prosthodont Soc. 2011 ;11(1):52-54.
Refbacks
- There are currently no refbacks.