INTRA ARTICULAR DISTAL RADIUS FRACTURES AND FIXED ANGLE VOLAR LOCKING PLATE FIXATION: A PROSPECTIVE STUDY

Dr. Hemeshwar Harshwardhan, Dr. Ashwani Jangir

Abstract


Background: Intra-articular distal radius fractures still a therapeutic challenge to orthopedic surgeons. With the advent of locking plates, the fixation of these fractures has been made better, specifically by Fixed Angle Volar Locking Plate. This study investigates the efficacy of these plates using volar approach, functional & radiological outcome evaluated.

Methods: This study was conducted at orthopedic department - JLN medical college & associated hospital Ajmer (Rajasthan). Twenty five patients with closed intra-articular distal radius fractures, with AO TYPE B2, B3, AND C fracture pattern, operated with Fixed Angle Locking Plate fixation using volar approach, were included in the study during the period of July 2018 to September 2019, with a minimum follow up of six months, radiological outcome was analysed (Sarmientos modification of Lindstorm criteria) and functional outcome recorded (Gartland and Werley’s demerit scoring system).

Results: With a mean age of 38.4 years and follow up of three months, the range of movement of the wrist was very satisfactory, and the mean grip strength was 85% of the opposite wrist. Functional parameters by Gartland and Werley showed a significant improvement in most of the patients during the follow‑up period(68% excellent,16% good,16% fair) and Radiological parameters were well maintained (Lindstorm criteria - 60% excellent,29% good,7% fair,4% poor) and The complication rate was less and insignificant.

Conclusions: Primary fixed angle volar plate fixation of intra-articular distal radius fracture provides a stable fixation that effective in anatomic realignment, allows early joint motion, owing to its fixation strength, thereby better functional & radiological outcomes and minimal complication.


Keywords


Fixed Angle Volar Locking plate, Distal radius, Gartand and Werley, Lindstorm criteria, Wrist

Full Text:

PDF

References


Court-Brown, Charles M.; Heckman, James D.; McQueen, Margaret M.; Ricci, William M.; (Iii), Paul Tornetta; McKee, Michael D. (2015). Rockwood and Green's fractures in adults. Court-Brown, Charles M.,, Heckman, James D.,, McQueen, Margaret M.,, Ricci, William M.,, Tornetta, Paul, III,, McKee, Michael D. (8th ed.). Philadelphia. ISBN 9781451175318. OCLC 893628028.

Cherubino P, Bini A, Marcolli D. Management of distal radius fractures: Treatment protocol and functional results. Injury 2010; 4: 1120-6.

Frykmann G. Fractures of the distal radius including sequelae shoulder-hand-finger syndrome, disturbance in the distal radioulnar joint and impairment of nerve function. A clinical and experimental study. Acta Orthop Scand J 1967; 108: 1-124.

Melone CP Jr. Open treatment for displaced articular fractures of the distal radius. Clin orthop 1986; 202: 103-11.

Fernandez DL. Malunion of the distal radius: current approach to management. Instr Course Lect 1993; 42: 99-113.

Solgaard S. Function after distal radius fracture. Acta Orthop Scand 1988;59(1):3942.

Orbay J, Fernandez Dl: Volar fixation for dorsally displaced fractures of the distal radius: a preliminary report. J Hand surg 2002;27a:205–215

Orbay J, Fernandez Dl: Volar fixed-angle plate fixation for unstable distal radius fractures in the elderly patient. J Hand surg 2004;29a:96–102.

Willis AA, Kutsumi K, Zobitz ME, Cooney WP. Internal fixation of dorsally displaced fractures of the distal part of the radius: A biomechanical analysis of volar plate fracture stability. JBJS Am. 2006;88(11):2411-7.

Nana AD, Joshi A, Lichtman DM. Plating of the Distal Radius. J Am Acad Orthop Surg. 2005;13(3):159-71.

Rozental TD, Blazar PE. Functional outcome and complications after volar plating for dorsally displaced, unstable fractures of the distal radius. J Hand Surg Am. 2006;31:359-65.

Leung F, Zhu L, Ho H, LuWW, Chow SP. Palmar plate fixation of AO type C2 fracture of distal radius using a locking compression plate--a biomechanical study in a cadavericmodel. J Hand Surg Br. 2003;28:263-6.

Jagodzinski NA, Singh T, Norris R, Jones J, Power D. Early results of a variable-angle volar locking plate for distal radius fractures: A bi-centre study. Orthopaedic Proceedings; 2012.

Chavhan AN et al Functional and radiological outcome in distal radius fractures treated with locking compression plate. Int J Res Med Sci 2017; 5:574-82.

Hakimi M, Jungbluth P, Windolf J, Wild M. Functional results and complications following locking palmar plating on the distal radius: a retrospective study. Journal Hand Surg. 2010;35(4):283–8.

Othman AY. Fixation of dorsally displaced distal radius fractures with volar plate. J Trauma 2009;66:1416‑20.


Refbacks