EVALUATION OF THE QUALITY INDICATORS IN HEMATOLOGY LABORATORY – GCRI STUDY
Abstract
Introduction: Quality indicators in a clinical laboratory are considered as useful tools for continual improvement of the laboratory services.
Aim: The aim of this study was to assess timely performance of the Gujarat Cancer & Research Institute (GCRI) service laboratories in three phases of testing – pre-analytical, analytical and post-analytical, in an effort to improve their performance.
Methodology: The study included an assessment of different quality indicators from central laboratory - Hematology, at GCRI which provide service for the patient care.
Results: Data obtained from a total of 490349 samples collected over a period of three years was used in the study. The overall error rate was found to be 2.72%. The commonly observed indicators were clotted sample (3.62%) followed by low quantity (0.99%) of samples during the pre-analytical phase. In the analytical phase, IQC failure (0.27%) was the most common in the three years study period, TAT outlier was 1.2%, during the post- analytical phase.
Conclusions: Quality indicators are important tools in improving the quality system in a clinical laboratory and patient care.
Keywords
Full Text:
PDFReferences
World Health Organization’s Regional Office for Africa. Resolution AFR/RC58/R2: Strengthening Public Health Laboratories in the WHO African Region: a critical need for
disease control. In: Final Report: 58th Session of the WHO Regional Committee for Africa. Yaounde, Republic of Cameroon: World Health Organization’s Regional Office for Africa,
; p11-13.
Agarwal R, Chaturvedi S, Chhillar N, Goyal R, Pant I, Tripathi CB. Role of Intervention on Laboratory Performance: Evaluation of Quality Indicators in a Tertiary Care Hospital. Indian J of Clin Biochem. 2012; 27: 61-68.
Carraro P, Plebani M. Errors in a stat laboratory: types and frequencies 10 years later. Clin Chem. 2007; 53:1338-42.
Codagnone F, Alencar S, Shcolnik W Chaves S, cSilva L , Henriques V, Spitz L. The use of indicators in the preanalytical phase as a laboratory management tool. J Bras Patol Med Lab 2014; 50: 100-104.
Plebani M, Sciacovelli L, Aita A, Padoan A, Chiozza ML. Quality indicators to detect pre-analytical errors in laboratory testing. Clin Chim Acta. 2014; 15; 432:44-8.
Furtado V, Shusaku S, Mendes M, Massakazu N. Usefulness of quality indicators in the management of clinical laboratories. J Bras Patol Med Lab 2011; 47:201-210.
Phlebani M. Quality specifications: self-pleasure for clinical laboratories or added value for patient management? Clin Chem Lab Med 2007; 45:462–6.
McCay L, Lemer C, Wu AW. Laboratory safety and the WHO World Alliance for Patient Safety. Clin Chim Acta 2009; 404:6-11.
International Organization for standardization ISO 15189: 2012-Medical laboratories requirements for quality and competence. Geneva, Switzerland. 2012. http://www.iso. Org.
Bureau of Indian Standards. Indian Standards Medical Laboratories- Particular Requirements for quality and competence. First Revision. New Delhi: Bureau of Indian Standards;2010.
Chawla R, Goswami B, Singh B, Chawla A, Gupta VK, Mallika V. Evaluating laboratory performance with quality indicators. Lab medicine. 2000; 41:297–300.
Goswami B, Singh B, Chawla R, Venkatesan M. Evaluation of errors in a clinical laboratory: a one-year experience. Evaluation of errors in a clinical laboratory: a one-year experience,
Clin Chem Lab Med; 2010; 48: 63-66.
Gupta V, Negi G, Harsh M, Harish C, Agarwal A, Shrivastava V. Utility of sample rejection rate as a quality indicator in developing countries. The journal of national accreditation board for hospitals & health care providers 2015;2(1):30-35.
Chawala R, Goswami B, Tayal B, Mallika B. Identification of the types of Pre-analytical Errors in Clinical Chemistry Laboratory: 1-Year Study at G.B Pant Hospital. Lab Medicinem 2010; 41:8993.
Soni S, Katara R, Nanera A, Goswami H, Vegad M. Sample rejection as a quality indicator for continual improvement of Laboratory Services, Tertiary Care Hospital. NJIRM; 2014:5: 72-75.
Chhillar N, Khurana S, Agarwal R, Singh NK. Effect of preanalytical errors on quality of laboratory medicine at a neuropsychiatry institute in north India. Indian J Clin Biochem 2011; 26:46-9.
Kirchner MJ, Funes VA, Adzet CB, Clar MV, Escuer MI, Girona JM et al. Quality indicators and specifications for key processes in clinical laboratories: a preliminary experience. Clin Chem Lab Med. 2007; 45:672-7.
Stark A, Jones BA, Chapman D, Well K, Krajenta R, Meier FA et al. Clinical laboratory specimen rejection: Association with the site of patient care and patients′ characteristics: Findings from a single health care organization. Arch Pathol Lab Med 2007; 131:588-92.
Guimarães AC, Wolfart M, Brisolara ML, Dani C. Causes of rejection of blood samples handled in the clinical laboratory of a University Hospital in Porto Alegre. Clin Biochem. 2012; 45:123-6.
Sangeeta Kulkarni1, Sachin Kale2, Urmila Ghodke et al. Evaluation of the Quality Indicators in Laboratories at National AIDS Research Institute, Pune, India.2017;8:47-51.
Refbacks