MINIMALLY INVASIVE PERCUTANEOUS PLATE OSTEOSYNTHESIS FOR PROXIMAL TIBIAL FRACTURES-A PROSPECTIVE STUDY
Abstract
Introduction:Proximal tibial fractures are most common in road traffic accidents,are difficult to manage due to limited soft tissue coverage. Conventional method of plate and screws can devitalize soft tissue. To overcome such complications MIPPO TECHNIQUE is widely used.
Methods:The functional outcome of proximal tibial fractures in 30 patients treated by MIPPO technique has been evaluated. These patients were followed for 6 months postoperatively and assessed by modified Rasmussen score.
Results:In our analysis of 30 patients ,18(60%) patients had excellent results, 9(30%) patients had good results, 3(10%)had fair outcome.
Discussion:Fracture of proximal tibia involves lot soft tissue damage,this compromised soft tissue condition must be considered while treating them. MIPPO is more of biological fixation with less soft tissue damage,hence wound healing is faster.
Keywords
Full Text:
PDFReferences
Campbell‟s operative orthopaedics; Fractures of lower extremity:Tibial plateau 2094-
Vol 3.
Kenneth. A. Egol and Kenneth J Koval , In: Fracture of proximal tibia: chapter 50, Rockwood and Green’s “Fracture in Adults”, Vol. 2, 6th edition, Lippincott Williams and Wilkins. pp. 1999.
Charles . M. Court-Brown, In: Fracture of tibia and fibula. Chapter 52, Rockwood and Green’s “Fracture in Adults” , Vol. 2, 6th edition, Lippincott Williams and Wilkins, pp. 2080
Schatzkar J, McBroom R, Bruce D. The tibial plateau fractures. Toronto Experience. ClinOrthop 1979;138:94.
Albuquerque, RP e, Hara R, Prado J, Schiavo L, Giordano V, &AmaralNP do.Epidemiological study on tibial plateau fractures at a level I traumacenter. ActaOrtopédicaBrasileira. (2013): 21(2), 109-15.
Chang-Wug Oh, Jong-Keon Oh, Hee-Soo Kyung et all. Double plating ofunstable proximal tibial fractures using minimally invasive percutaneousosteosynthesis technique. Injury ActaOrthopaedica 2006; 77(3):524-530.
Raza H, Hashmi P, Abbas K, Hafeez K. Minimally invasive plate osteosynthesis for tibial plateau fractures. J Orthopaedic Surgery. 2012;20(1):42–47
Rohra N, Suri HS, Gangrade K. Functional and Radiological Outcome of Schatzker type V and VI Tibial Plateau Fracture Treatment with Dual Plates with Minimum 3 years follow-up: A Prospective Study. J ClinDiagn Res. 2016;10(5):RC05–RC10.
Refbacks